Brand Name : HOLD-ONE
Certification : IEC 60502
Place of Origin : China
MOQ : 500m
Price : 0.10-30.99USD/m
Payment Terms : L/C, D/A, D/P, T/T
Supply Ability : 1000km per month
Delivery Time : 10 Days
Packaging Details : Wooden Drum or Steel Drum
Phase Conductor : Aluminium
Neutral Conductor : Aluminum Alloy
Insulation : PE
Cores No. : 5
Rated Voltage : 0.6/1 KV
Application : Aerial Electrics Transmitting
PE Insulation Five Core Aerial Drop Cable STANDARD NF C 33-209 NFA 2X
Construction
a)Phase - The phase conductor shall be of H68 Condition aluminium conductor and compacted circular stranded.
b)Neutral or messenger - The Neutral or messenger conductor shall be of aluminium alloy conductor and compacted circular stranded c)Street Lighting- The street lighting conductors shall be of H68 condition aluminium conductor and compacted circular stranded..
The phase, neutral conductors shall be extruded with polyethylene(PE) as insulation.
Schedule of technical particulars
Phase conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
Minimum number of wires | 6 | 6 | 6 | 12 | 15 | 15 | 30 | 30 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.4 | 1.4 | 1.6 | 1.6 | 1.8 | 2.0 |
Diameter of insulated core | mm | 8.5 | 9.5 | 11.2 | 13.0 | 15.1 | 16.6 | 18.4 | 20.6 |
Max. DC resistance at 20℃ | ohm/km | 1.20 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 | 0.164 |
Current rating at still wind, ambient | A | 84 | 104 | 129 | 167 | 209 | 246 | 283 | 332 |
temperature=30℃ | |||||||||
Conductor temperature=75℃ | |||||||||
Messenger conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.6 | 1.6 |
Diameter of insulated core | mm | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
Max. DC resistance at 20℃ | ohm/km | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
Calculated breaking load | kN | 6.4 | 6.4 | 8.9 | 12.1 | 18.0 | 18.0 | 24.2 | 30.8 |
Street lighting conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.6 | 1.6 |
Diameter of insulated core | mm | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
Max. DC resistance at 20℃ | ohm/km | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
Completed cable | |||||||||
Approx. overall diameter | mm | 23.2 | 25.6 | 30.0 | 34.9 | 40.6 | 44.1 | 49.2 | 54.9 |
Approx. weight of cable | kg/km | 470 | 560 | 740 | 980 | 1330 | 1580 | 1940 | 2410 |
Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 500 | 500 | 500 | 500 |
STANDARD NF C 33-209
NFA 2X
Phases | Neutral/Messenger | ||||||||
Distribution Lines | Pub. Lighting | ||||||||
Cable Type | Number of | Number of | Avarage | Resistance | Conductance | Number of | Avarage | Rated | Resistance |
core | wire | diameter | at 20℃ | at 30℃ | core | diameter | Strength | at 20℃ | |
mm² | mm² | PCS | mm | ohm/km | A | mm² | mm | kN | ohm/km |
2x16 | 2x16 | 7 | 4.6 | 1.91 | 93 | - | - | - | - |
2x35 | 2x35 | 7 | 5.9 | 1.20 | 122 | - | - | - | - |
2x35 | 2x35 | 7 | 6.9 | 0.868 | 129 | - | - | - | - |
2x50 | 2x50 | 7 | 8.1 | 0.641 | 158 | - | - | - | - |
4x16 | 4x16 | 7 | 4.6 | 1.91 | 83 | - | - | - | - |
4x25 | 4x25 | 7 | 5.9 | 1.20 | 111 | - | - | - | - |
4x35 | 4x35 | 7 | 6.9 | 0.868 | 131 | - | - | - | - |
3x25+54.6 | 3x25 | 7 | 5.9 | 1.20 | 112 | - | 9.6 | 16.0 | 0.63 |
3x25+1x16+54.6 | 3x25 | 7 | 5.9 | 1.20 | 112 | 1x16 | 9.6 | 16.0 | 0.63 |
3x25+2x16+54.6 | 3x25 | 7 | 5.9 | 1.20 | 112 | 2x16 | 9.6 | 16.0 | 0.63 |
3x35+54.6 | 3x35 | 7 | 6.9 | 0.868 | 138 | - | 9.6 | 16.0 | 0.63 |
3x35+1x16+54.6 | 3x35 | 7 | 6.9 | 0.868 | 138 | 1x16 | 9.6 | 16.0 | 0.63 |
3x35+2x16+54.6 | 3x35 | 7 | 6.9 | 0.868 | 138 | 2x16 | 9.6 | 16.0 | 0.63 |
3x50+54.6 | 3x50 | 7 | 8.1 | 0.641 | 168 | - | 9.6 | 16.0 | 0.63 |
3x50+1x16+54.6 | 3x50 | 7 | 8.1 | 0.641 | 168 | 1x16 | 9.6 | 16.0 | 0.63 |
3x50+2x16+54.6 | 3x50 | 7 | 8.1 | 0.641 | 168 | 2x16 | 9.6 | 16.0 | 0.63 |
3x70+54.6 | 3x70 | 12 | 9.7 | 0.443 | 213 | - | 9.6 | 16.0 | 0.63 |
3x70+1x16+54.6 | 3x70 | 12 | 9.7 | 0.443 | 213 | 1x16 | 9.6 | 16.0 | 0.63 |
3x70+2x16+54.6 | 3x70 | 12 | 9.7 | 0.443 | 213 | 2x16 | 9.6 | 16.0 | 0.63 |
3x70+1x25+54.6 | 3x70 | 12 | 9.7 | 0.443 | 213 | 1x25 | 9.6 | 16.0 | 0.63 |
3x70+2x25+54.6 | 3x70 | 12 | 9.7 | 0.443 | 213 | 2x25 | 9.6 | 16.0 | 0.50 |
3x70+70 | 3x70 | 12 | 9.7 | 0.443 | 213 | - | 10.2 | 20.6 | 0.50 |
3x70+1x16+70 | 3x70 | 12 | 9.7 | 0.443 | 213 | 1x16 | 10.2 | 20.6 | 0.50 |
3x70+2x16+70 | 3x70 | 12 | 9.7 | 0.443 | 213 | 2x16 | 10.2 | 20.6 | 0.50 |
3x95+70 | 3x95 | 12 | 11.5 | 0.320 | 258 | - | 10.2 | 20.6 | 0.50 |
3x95+1x16+70 | 3x95 | 12 | 11.5 | 0.320 | 258 | 1x16 | 10.2 | 20.6 | 0.50 |
3x95+2x16+70 | 3x95 | 12 | 11.5 | 0.320 | 258 | 2x16 | 10.2 | 20.6 | 0.50 |
3x120+70 | 3x120 | 12 | 12.8 | 0.253 | 300 | - | 10.2 | 20.6 | 0.50 |
3x120+1x16+70 | 3x120 | 19 | 12.8 | 0.253 | 300 | 1x16 | 10.2 | 20.6 | 0.50 |
3x120+2x16+70 | 3x120 | 19 | 12.8 | 0.253 | 300 | 2x16 | 10.2 | 20.6 | 0.50 |
3x150+70 | 3x150 | 19 | 14.5 | 0.206 | 344 | - | 10.2 | 20.6 | 0.50 |
3x150+1x16+70 | 3x150 | 19 | 14.5 | 0.206 | 344 | 1x16 | 10.2 | 20.6 | 0.50 |
3x150+2x16+70 | 3x150 | 19 | 14.5 | 0.206 | 344 | 2x16 | 10.2 | 20.6 | 0.50 |
3x120+95 | 3x120 | 19 | 12.8 | 0.253 | 300 | - | 12.9 | 27.9 | 0.343 |
3x120+1x16+95 | 3x120 | 19 | 12.8 | 0.253 | 300 | 1x16 | 12.9 | 27.9 | 0.343 |
3x120+2x16+95 | 3x120 | 19 | 12.8 | 0.253 | 300 | 2x16 | 12.9 | 27.9 | 0.343 |
3x150+95 | 3x150 | 19 | 14.5 | 0.206 | 344 | - | 12.9 | 27.9 | 0.343 |
3x150+1x16+95 | 3x150 | 19 | 14.5 | 0.206 | 344 | 1x16 | 12.9 | 27.9 | 0.343 |
3x150+2x16+95 | 3x150 | 19 | 14.5 | 0.206 | 344 | 2x16 | 12.9 | 27.9 | 0.343 |
1 KV PE Insulated Aerial Bunch Cable 5 Cores With Neutral Conductor IEC 60502 Images |